Horizontal Szl Double Drum Chain Grate Coal Fired Steam Boiler

 

         Merchandise Description

  • 1.The boiler shall adopt double drum,monolayer arrangement,compact structure,as well as large heating surfaces which aremore ten% than people of identical types of products,that includes the following benefits these kinds of as enough output,risk-free and reliableoperation,quick building period,minimal set up price ect.

  • two.The style of cyclone reburning chamber in furnace resulted in the decrease of dust contained in the flue gas.At the identical time,incandescent carbon black particles shall burn up even more,boosting the boiler thermal efficiency,decreasing fuel blackness,as a end result,the gas emission concentration shall satisfy the requirements of grade A environmental security spot.

  • three.The grate shall use the technologies patent of modest roller construction,boundary grate and so on,improving the procedure dependability of the boiler.   

  • 4.Considering that the adoption of technology patent for the sealed wind chamber and bilateral grate air sign up,and the software of machining cone seal structure to grate modifying air eauipment,the sensitivity of the grate shall be improved.

    Boiler principal entire body will be loaded on the 20′ or 40′ FR(flat rack) containers with weather conditions fabric,boiler equipment will be packed with plywood packing containers and loaded in the 20-toes or forty-ft GP(CZPT) containers.

    The parameter of boiler

Item 
 Boiler type
 Model

SZL6
-one.25/
1.6/two.5
-AII

SZL8
-1.25/
one.six/two.five
-AII

SZL10
-one.25/
one.six/2.five
-AII

SZL10
-1.twenty five/
one.six/2.5
-AII

SZL15
-1.25/
one.6/2.5
-AII

SZL20
-1.25/
1.six/2.5
-AII

SZL25
-one.25/
one.six/two.five
-AII

Evaporation capacity

T/h

6

eight

ten

12

15

20

25

Working pressure

Mpa

1.25/
1.six/
2.5

1.twenty five/
1.6/
two.five

1.25/
one.6/
2.five

1.25/
1.six/
2.5

1.twenty five/
1.6/
2.five

1.25/
1.six/
2.five

one.25/
one.six/
two.5

Steam temperature

ºC

194/
204/
226

194/
204/226

194/
204/226

194/
204/
226

194/
204/
226

194/
204/
226

194/
204/
226

Inlet water  temperature

ºC

twenty

20

20

twenty

one zero five

a hundred and five

105

Heating efficiency

%

≥78

≥78

≥80

≥80

≥81

≥81

≥81

Area of boiler heating 
area

147.8

a hundred seventy five

220

388

443

578

626

Area of stoker

seven.6

9.six

eleven.seventy two

14.2

seventeen.two

22.six

26.three

Coal CZPT

 

II type bituminous,low heat capability:17700-21000KJ/kg

Water pump

Model

 

2GC-5×6

2½GC-6×6

DG12×7

DG15-35×5

DG15-35×5

DG25-35×5

DG46×30

Motor
 power

Kw

fifteen/eighteen.5

15/18.five

18.five/22

22/thirty

22/30

thirty/37

37/forty five

Blast fan

Model

 

G6-41-13

NO7.1A

G6-forty one-13

NO8.5A

G6-41-13

NO8.5A

G6-forty one-13

NO8.5A

G6-forty one-13

NO8.5A

G6-73-11

NO11D

G4-sixty eight-10D

Air flow

M³/h

5349-one 0571

9369-18137

9369-18137

9369-18137

9369-18137

36100

33173-

58856

Wind 
strain

Pa

1697-2270

2535-3391

2535-3391

2535-3391

2535-3391

2730

2313-3401

Motor  
energy

Kw

7.5

18.five

18.5

18.5

18.five

37

forty five

Induced 
draft fan

Product

 

Y6-forty one-thirteen

NO10C

Y6-41-13

NO11.2d

Y6-41-thirteen

NO11.Second

Y6-forty one-thirteen

NO11.2d

Y8-39-13

NO10D

GY20-fifteen

Y4-68

NO12.5D

Ventilation

M³/h

32144-

16604

41773-

21578

41773-

21578

41773-

21578

4500

73308

60611-

11571

Wind 
stress

Pa

2575-3444

2764-3697

2764-3697

2764-3697

3205

3515

3765-2589

Motor 
Energy

Kw

37

forty five

forty five

fifty five

ninety

a hundred and ten

132

Maximum size for 
shipment

M

7.83×3.34

×3.forty six

eight.82×3.34

×3.46

eight.0×3.five

×2.7

seven.2×3.3

×3.6

eight.0×3.3    ×3.6

10.6×3.35

×3.69

10.8×4.46

×3.seventy six

Maximum weight for 
shipment

T

forty eight/fifty one/53

fifty six/fifty eight/sixty

ninety six/97/ninety eight

102/103

/104

107/108

/109

152/154

/156

210/212

/214

CZPTer circumstance

 

 

Horizontal Szl Double Drum Chain Grate Coal Fired Steam Boiler